OSN3500 SDH单板发光功率和传输距离及接收灵敏度指标
OSN3500 N4SL64支持CWDM和DWDM彩色光接口,光接口采用LC连接器。CWDM光接口支持70km传输距离,DWDM光接口支持40km和80km传输距离。N4SL64支持I-64.1、S-64.2b、Le-64.2、P1L1-2D2和V-64.2b(加BA,PA和DCU)的标准光接口。I-64.1、S-64.2b、Le-64.2和V-64.2b光接口特性符合ITU-T G.691建议,P1L1-2D2光接口特性符合ITU-T G.959建议。
| 单板名称 | 光模块 | 最大传输距离(km) | 光纤类型 | ||||
|---|---|---|---|---|---|---|---|
| 支持光口类型 | 平均发送功率 | 接收灵敏度(dBm) | 最小过载点(dBm) | ||||
| 最小(dBm) | 最大(dBm) | ||||||
| SL1、SL1A | I-1 | –15 | –8 | –23 | –8 | 2 | 单模LC | 
| S-1.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | |
| L-1.1 | –5 | 0 | –34 | –10 | 40 | 单模LC | |
| L-1.2 | –5 | 0 | –34 | –10 | 80 | 单模LC | |
| Ve-1.2 | –3 | 0 | –34 | –10 | 100 | 单模LC | |
| SLQ1、SLQ1A | I-1 | –15 | –8 | –23 | –8 | 2 | 单模LC | 
| S-1.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | |
| L-1.1 | –5 | 0 | –34 | –10 | 40 | 单模LC | |
| L-1.2 | –5 | 0 | –34 | –10 | 80 | 单模LC | |
| Ve-1.2 | –3 | 0 | –34 | –10 | 100 | 单模LC | |
| Ie-1 | -19 | -14 | –30 | –14 | 2 | 多模LC | |
| SLT1 | S-1.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | 
| SL4、SL4A、SLD4、SLD4A、SLQ4、SLQ4A | I-4 | –15 | –8 | –23 | –8 | 2 | 单模LC | 
| S-4.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | |
| L-4.1 | –3 | 2 | –28 | –8 | 40 | 单模LC | |
| L-4.2 | –3 | 2 | –28 | –8 | 80 | 单模LC | |
| Ve-4.2 | –3 | 2 | –34 | –13 | 100 | 单模LC | |
| SL16 | L-16.2 | –2 | 3 | –28 | –9 | 80 | 单模LC | 
| L-16.2Je | 5 | 7 | –28 | –9 | 100 | 单模LC | |
| V-16.2Je(BA) | 不加BA: –2 加BA: 13 | 不加BA:3 加BA:15 | –28 | –9 | 140 | 单模LC | |
| U-16.2Je(BA+PA) | 不加BA和PA:–2 加BA:15 | 不加BA和PA:3 加BA:18 | 不加PA和BA:–28 加PA:–32 | 不加PA和BA:–9 加PA:–10 | 170 | 单模LC | |
| SL16A | I-16 | –10 | –3 | –18 | –3 | 2 | 单模LC | 
| S-16.1 | –5 | 0 | –18 | 0 | 15 | 单模LC | |
| L-16.1 | –2 | 3 | –27 | –9 | 40 | 单模LC | |
| L-16.2 | –2 | 3 | –28 | –9 | 80 | 单模LC | |
| SLD16 | I-16 | –10 | –3 | –18 | –3 | 2 | 单模LC | 
| S-16.1 | –5 | 0 | –18 | 0 | 15 | 单模LC | |
| L-16.1 | –2 | 3 | –27 | –9 | 40 | 单模LC | |
| L-16.2 | –2 | 3 | –28 | –9 | 80 | 单模LC | |
| SLQ16 | I-16 | –10 | –3 | –18 | –3 | 2 | 单模LC | 
| S-16.1 | –5 | 0 | –18 | 0 | 15 | 单模LC | |
| L-16.1 | –2 | 3 | –27 | –9 | 40 | 单模LC | |
| L-16.2 | –2 | 3 | –28 | –9 | 80 | 单模LC | |
| SLO16 | I-16 | –10 | –3 | –18 | –3 | 2 | 单模LC | 
| S-16.1 | –5 | 0 | –18 | 0 | 15 | 单模LC | |
| L-16.1 | –2 | 3 | –27 | –9 | 40 | 单模LC | |
| L-16.2 | –2 | 3 | –28 | –9 | 80 | 单模LC | |
| SL64 | I-64.1 | –6 | –1 | –11 | –1 | 2 | 单模LC | 
| I-64.2 | –5 | –1 | –14 | –1 | 25 | 单模LC | |
| S-64.2b | –1 | 2 | –14 | –1 | 40 | 单模LC | |
| L-64.2b(BA) | 不加BA:–4 加BA:13 | 不加BA:2 加BA:15 | –14 | –1 | 80 | 单模LC | |
| P1L1-2D2 | 0 | 4 | –24 | –7 | 80 | 单模LC | |
| Le-64.2 | 0 | 4 | –21 | –8 | 60 | 单模LC | |
| Ls-64.2 | 4 | 7 | –21 | –8 | 80 | 单模LC | |
| V-64.2b(BA+PA+DCU) | 不加BA、PA和DCU:–4 加BA:13 | 不加BA、PA和DCU:–1 加BA:15 | 不加BA、PA和DCU:–14 加PA:-26 | –1 | 120 | 单模LC | |
| SL64A | I-64.2 | –5 | –1 | –14 | –125 | 25 | 单模LC | 
| S-64.2b | –1 | 2 | –14 | –1 | 40 | 单模LC | |
| L-64.2b(BA) | 不加BA:–4 加BA:13 | 不加BA:2 加BA:15 | –14 | –1 | 80 | 单模LC | |
| Le-64.2 | 0 | 4 | –21 | –8 | 60 | 单模LC | |
| Ls-64.2 | 4 | 7 | –21 | –8 | 80 | 单模LC | |
| V-64.2b(BA+PA+DCU) | 不加BA、PA和DCU:–4 加BA:13 | 不加BA、PA和DCU:–1 加BA:15 | 不加BA、PA和DCU:–14 加PA:-26 | –1 | 120 | 单模LC | |
| SLD64 | I-64.1 | –6 | –1 | –11 | –1 | 2 | 单模LC | 
| S-64.2b | –1 | 2 | –14 | –1 | 40 | 单模LC | |
| SLQ41 | I-1 | –15 | –8 | –23 | –8 | 2 | 单模LC | 
| S-1.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | |
| L-1.1 | –5 | 0 | –34 | –10 | 40 | 单模LC | |
| L-1.2 | –5 | 0 | –34 | –10 | 80 | 单模LC | |
| Ve-1.2 | –3 | 0 | –34 | –10 | 100 | 单模LC | |
| I-4 | –15 | –8 | –23 | –8 | 2 | 单模LC | |
| S-4.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | |
| L-4.1 | –3 | 2 | –28 | –8 | 40 | 单模LC | |
| L-4.2 | –3 | 2 | –28 | –8 | 80 | 单模LC | |
| Ve-4.2 | –3 | 2 | –34 | –13 | 100 | 单模LC | |
| SLH41 | S-1.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | 
| L-1.1 | –5 | 0 | –34 | –10 | 40 | 单模LC | |
| S-4.1 | –15 | –8 | –28 | –8 | 15 | 单模LC | |
本章相关技术资料和SDH设备故障处理流程由深圳市鼎为网络技有限公司提供(www.szdingwei.net),转载请保留!华为SDH光传输设备,SDH传输设备销售
- 上一篇:OSN1500 SDH传输设备散热不良导致单板环境温度过高 2018-9-7
- 下一篇:OSN3500 SDH类单板FEC常用白色光接口指标 2018-8-31




 
				 
			 
				 
			 
			 
				