Optix OSN1500 SSQ5CXLQ4单板告警清单
OSN1500 ECXL(旧背板)
APS_FAIL | APS_INDI | BD_STATUS |
CHIP_FAIL | BUS_ERR | CHIP_ABN |
EXT_SYNC_LOS | CLK_NO_TRACE_MODE | COMMUN_FAIL |
HSC_UNAVAIL | FPGA_ABN | HARD_BAD |
LPS_UNI_BI_M | K1_K2_M | K2_M |
NO_BD_SOFT | LTI | MS_APS_INDI_EX |
OTH_HARD_FAIL | OOL | OTH_BD_STATUS |
SWITCH_DISABLE | POWER_ABNORMAL | S1_SYN_CHANGE |
SYNC_F_M_SWITCH | SYN_BAD | SYNC_C_LOS |
TEST_STATUS | SYNC_LOCKOFF | TEMP_OVER |
W_OFFLINE | W_R_FAIL | TIME_NOT_SUPPORT |
TIME_NO_TRACE_MODE | TIME_LOS | TIME_FORCE_SWITCH |
EXT_TIME_LOC | NP1_SW_INDI | NP1_SW_FAIL |
RPS_INDI | SERVCHIP_ABN |
OSN1500 UCXL(新背板)
APS_FAIL | APS_INDI | BD_STATUS |
CHIP_FAIL | BUS_ERR | CHIP_ABN |
EXT_SYNC_LOS | CLK_NO_TRACE_MODE | COMMUN_FAIL |
HARD_BAD | EXT_TIME_LOC | FPGA_ABN |
K2_M | HSC_UNAVAIL | K1_K2_M |
MS_APS_INDI_EX | LPS_UNI_BI_M | LTI |
NP1_SW_INDI | NO_BD_SOFT | NP1_SW_FAIL |
PATCH_NOT_CONFIRM | OOL | PATCH_ERR |
PRBS_TEST | PATCHFILE_NOTEXIST | POWER_ABNORMAL |
SYN_BAD | RPS_INDI | S1_SYN_CHANGE |
SYNC_LOCKOFF | SYNC_C_LOS | SYNC_F_M_SWITCH |
TIME_FORCE_SWITCH | TEMP_OVER | TEST_STATUS |
W_OFFLINE | TIME_LOS | TIME_NO_TRACE_MODE |
TIME_NOT_SUPPORT | SERVCHIP_ABN |
GSCC
APS_MANUAL_STOP | BD_AT_LOWPOWER | BD_NOT_INSTALLED |
BD_STATUS | BOOTROM_BAD | CFCARD_FAILED |
CFCARD_OFFLINE | CFCARD_W_R_DISABLED | COMMUN_FAIL |
DBMS_ERROR | DBMS_PROTECT_MODE | DCC_CHAN_LACK |
FPGA_ABN | HARD_BAD | HSC_UNAVAIL |
MSSW_DIFFERENT | NE_POWER_OVER | NESF_LOST |
NESTATE_INSTALL | LAN_LOC | PATCH_ERR |
PATCH_PKGERR | PATCH_NOT_CONFIRM | PATCHFILE_NOTEXIST |
POWER_ABNORMAL | POWER_FAIL | REG_MM |
RINGMAPM_MM | RTC_FAIL | SECU_ALM |
SQUTABM_MM | SWDL_ACTIVATED_TIMEOUT | SWDL_AUTOMATCH_INH |
SWDL_INPROCESS | SWDL_CHGMNG_NOMATCH | SWDL_COMMIT_FAIL |
SWDL_NEPKGCHECK | TEMP_OVER | SWDL_ROLLBACK_FAIL |
SYNC_FAIL | BIOS_STATUS | WRG_BD_TYPE |
CFCARD_FULL | PATCH_DEACT_TIMEOUT | NP1_MANUAL_STOP |
PATCH_ACT_TIMEOUT | STORM_CUR_QUENUM_OVER | LCS_DAYS_OF_GRACE |
LCS_EXPIRED | LCS_FILE_NOT_EXIST | SYSLOG_COMM_FAIL |
SEC_RADIUS_FAIL | NE_CFG_CONFLICT | PASSWORD_NEED_CHANGE |
SSL_CERT_NOENC | M_S_SW | PWD_ENCRYPT_RISK |
Q2SLQ41
R_LOS | R_LOF | R_LOF |
R_LOC | B1_EXC | B1_SD |
J0_MM | B2_EXC | B2_SD |
MS_AIS | MS_RDI | MS_REI TF |
IN_PWR_ABN | OUT_PWR_ABN | LSR_WILL_DIE |
LSR_COOL_ALM | TEM_HA | TEM_LA |
LASER_MOD_ERR | LASER_SHUT | LSR_NO_FITED |
TEST_STATUS | ALM_ALS | TC_DEG |
FSELECT_STG | OH_LOOP | TC_EXC |
TC_LTC | NO_BD_SOFT | TC_INCAIS |
TC_RDI | TC_ODI | TC_OEI |
TC_UNEQ | TC_REI | TC_TIM |
TR_LOC | ALM_AU3AIS | ALM_AU3B3OVER |
BD_STATUS | T_LOSEX | COMMUN_FAIL |
ALM_AU3RDI | ALM_AU3B3SD | POWER_ABNORMAL |
ALM_AU3TIM | ALM_AU3REI | ALM_AU3LOP |
AU_LOP | ALM_AU3UNEQ | ALM_AU3SLM |
HP_UNEQ | HP_TIM | AU_AIS |
B3_EXC | HP_RDI | HP_SLM |
C2_PDI | B3_SD | HP_REI |
HP_LOM | FPGA_ABN | C2_VCAIS |
LP_UNEQ_VC12 | LOOP_ALM | SLAVE_WORKING |
BIP_SD | TU_AIS_VC12 | LP_TIM_VC12 |
LP_TIM_VC3 | BIP_EXC | TU_LOP_VC12 |
TU_LOP_VC3 | LP_UNEQ_VC3 | TEMP_OVER |
PS | B3_EXC_VC3 | TU_AIS_VC3 |
R_OOF | MOD_TYPE_MISMATCH | B3_SD_VC3 |
BIP8_ECC | AU_CMM | LSR_INVALID |
SPARE_PATH_ALM | W_R_FAIL | CHIP_FAIL |
TIME_NOT_SUPPORT |